These original questions focus on concepts that show up in backflow tester courses and cross-connection control training: backsiphonage, backpressure, hazard classification, assemblies, testing records, containment, and local authority.

  1. Question 1

    Backsiphonage

    A water main break causes pressure in a distribution main to drop below atmospheric pressure. Which backflow condition is most likely?

    • ABackpressure
    • BBacksiphonage
    • CThermal expansion
    • DWater hammer

    Correct answer: B. Backsiphonage

    Backsiphonage happens when negative or reduced supply pressure pulls water backward through a cross-connection.

  2. Question 2

    Backpressure

    A boiler system operates at a higher pressure than the potable supply. What hazard does this create if the connection is unprotected?

    • ABackpressure forcing boiler water toward the potable system
    • BLoss of chlorine residual from sunlight
    • CSediment settling in a storage tank
    • DCavitation at a pump impeller

    Correct answer: A. Backpressure forcing boiler water toward the potable system

    Backpressure occurs when downstream pressure exceeds supply pressure and can push non-potable water back toward the public water system.

  3. Question 3

    Air gaps

    Why is an approved air gap considered strong backflow protection?

    • AIt adds chlorine at the point of use
    • BIt creates physical separation between potable and non-potable water
    • CIt reduces pipe friction losses
    • DIt records test results automatically

    Correct answer: B. It creates physical separation between potable and non-potable water

    An air gap breaks the connection completely by separating the supply outlet from the receiving vessel flood level rim.

  4. Question 4

    Assemblies

    Which assembly is commonly used where a high-hazard condition requires protection against both backsiphonage and backpressure?

    • AReduced pressure principle assembly
    • BAtmospheric vacuum breaker
    • CSingle check valve
    • DHose bibb vacuum breaker only

    Correct answer: A. Reduced pressure principle assembly

    An RP assembly is a testable assembly commonly used for high-hazard conditions when both backsiphonage and backpressure protection are needed.

  5. Question 5

    Testing

    What is the main reason backflow assemblies are tested periodically?

    • ATo confirm the assembly still operates as designed
    • BTo raise system pressure
    • CTo measure water hardness
    • DTo replace cross-connection surveys

    Correct answer: A. To confirm the assembly still operates as designed

    Internal checks, relief valves, and shutoff valves can fail or foul. Testing verifies the assembly is still providing the required protection.

  6. Question 6

    Containment

    Containment protection is usually installed where?

    • AAt the customer's service connection or meter area
    • BOnly at laboratory sinks
    • COnly inside chemical feed rooms
    • DAt every hydrant in the distribution system

    Correct answer: A. At the customer's service connection or meter area

    Containment protects the public water system by controlling hazards at or near the service connection.

  7. Question 7

    Cross-connection surveys

    What is the purpose of a cross-connection survey?

    • ATo identify actual or potential connections between potable water and contaminants
    • BTo calculate detention time in a clearwell
    • CTo set pump rotation schedules
    • DTo choose a coagulant dose

    Correct answer: A. To identify actual or potential connections between potable water and contaminants

    A survey looks for actual or potential cross-connections and helps determine what protection is needed.

  8. Question 8

    Hazard classification

    A connection to a chemical mixing tank is typically treated as what kind of hazard?

    • ANo hazard
    • BAesthetic hazard only
    • CHigh health hazard
    • DPressure-zone boundary only

    Correct answer: C. High health hazard

    Chemical systems can introduce substances that may cause illness, so they are commonly treated as high health hazards.

  9. Question 9

    Records

    After a tester completes an assembly test, why is the test report important?

    • AIt documents the assembly, result, tester, date, and any repairs for the water supplier or authority
    • BIt replaces the need for future testing
    • CIt changes the water system's disinfectant residual
    • DIt certifies the building plumbing design forever

    Correct answer: A. It documents the assembly, result, tester, date, and any repairs for the water supplier or authority

    Backflow programs depend on records showing what was tested, who tested it, whether it passed, and what corrective work was done.

  10. Question 10

    Local authority

    Why should a tester candidate check local rules even after reading state requirements?

    • ALocal water suppliers or plumbing authorities may set accepted tester lists, forms, reporting systems, or testing frequency
    • BState rules never apply to backflow
    • CLocal rules only cover wastewater treatment plants
    • DBackflow testing is identical in every jurisdiction

    Correct answer: A. Local water suppliers or plumbing authorities may set accepted tester lists, forms, reporting systems, or testing frequency

    Backflow certification and reporting often involve state rules plus local water supplier, plumbing, or health department requirements.

What to study next

If these questions feel unfamiliar, start with the concept guide, then review water distribution topics like pressure, valves, and customer service connections.

Cross-connection control guide →Backflow lesson →Pressure and head math →